Search Issue Tracker
Fixed
Votes
0
Found in
2021.3.39f1
2022.3.31f1
6000.0.4f1
Issue ID
UUM-72969
Regression
No
[Linux][Steam Deck] Screen values are incorrect when using Steam Deck in Desktop Mode
Reproduction steps:
1. Open the attached “BugRepro” project
2. Build the project for Windows Platform
3. On Steam Deck, switch to Desktop Mode
4. Connect a keyboard to Steam Deck
5. Transfer the Build to the Steam Deck
6. Add the Build Player executable to Steam as a Non-Steam Game
7. Set it to use Proton Experimental
8. Launch the Player
9. In the upper right corner, observe the “CurrentRes” resolution value
10. Press ALT + ENTER to toggle full-screen mode
11. In the upper right corner, observe the “CurrentRes” resolution value
12. Change screen resolution
13. Observe resolutions
Expected results: In Desktop Mode, when toggling to Fullscreen, the Player sets the resolution to take up all of the screen space (1280 x 800), just like in Gaming Mode. When changing screen resolution, the resolution values are immediately updated in Player, just like in Windows.
Actual results: In Desktop Mode, toggling Player to Fullscreen sets the Player resolution to 800x800, instead of 1280x800. When changin screen resolution, the resolution values stay the same, even after toggling between fullscreen and windowed modes.
Reproduced with: 2021.3.39f1, 2022.3.31f1, 6000.0.4f1
Reproduced on: SteamOS
Not reproduced on: Ubuntu 22.04 + Proton, Windows 10
Comments (1)
-
LinkoVitch
Sep 17, 2024 12:40
Can you post the link to the duplicate issue so that I can follow that, thanks.
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Editor crashes and a window with "GetManagerFromContext: pointer to object of manager 'MonoManager' is NULL (table index 5)" error is shown when launching a freshly created project
- Editor Windows dragging behavior is erratic/glitchy when a specific multi-display setup is used and the Editor window is not on the main display
- Meta Quest missing an icon in Build Profiles window in U6.0
- Foldout arrow indent is misaligned in the Inspector when used for Arrays or Lists
- Material import pipeline strips properties when it is added with a script
Resolution Note:
Fixed by another internal issue: UUM-64956: Screen.SetResolution does change its value when the resolution is changed through Linux settings