Search Issue Tracker
Not Reproducible
Votes
0
Found in [Package]
9.0.0-preview.2
Issue ID
1230080
Regression
No
[URP] Certain settings are not applied to all cameras when multi-editing in the Inspector
How to reproduce:
1. Open the attached project named "Case_1230080"
2. Open the SampleScene
3. Select all of the cameras in the "CameraArray" gameObject
4. Set the Volume Mask to Nothing
5. Observe that the Inspector shows that every camera has its Volume Mask set to Nothing
6. Check individual cameras one by one
Expected result: All cameras have their Volume Mask set to the same value as previously shown by the Inspector while multi-editing
Actual result: Only one camera has its Volume Mask changed
Reproducible with: 2018.4.20f1, 2019.3.7f1, 2020.1.0b4, 2020.2.0a5
Could not test with: 2017.4.38f1(No package manager)
Reproducible with package versions: 4.1.0, 7.3.1, 8.0.1, 9.0.0-preview.2
Notes:
1. Settings affected Dithering, Stop Nan, Anti-aliasing, Post Processing, Volume Mask, Depth Texture, Opaque Texture
2. Does not reproduce with HDRP
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Colliders of GameObject with Rigidbody component fail to collide with another GameObject when Rigidbody becomes Kinematic
- Shader cache uploads occur when the "Upload" parameter is disabled in the Cache Server settings
- "ApplySingleProperty clear overrides error" error when applying SerializedReference override to Prefab's nested Prefab
- About Unity window shows extended version numbers including staging tag
- Mono release JIT incorrectly replaces long multiplication with a left-shift operation
Resolution Note:
Does no longer reproduce with URP 9.0.0-preview.35