Search Issue Tracker
Fixed in 0.8.0-preview.1
Votes
0
Found in [Package]
0.6.0-preview.1
Issue ID
1228992
Regression
No
Profile Analyzer - Large microsecond time listings are drawn under the 'Jump to frame' buttons in the Marker Summary section
How to reproduce:
1. Download the user-submitted data file(capture.pdata)
2. Create a new Unity project and import the Profile Analyzer package
3. Load the capture
4. Select the 'EditorLoop' Marker
5. In the Filters section set the Units to 'Microseconds'
6. See the Marker Summary section, Top 3(or more) 'by frame costs' listings
Expected result: the microsecond text is not drawn under the buttons
Actual result: text from some of the entries is drawn under the buttons(e.g. entry #3 - 32409us)
Reproducible with: 2018.4.19f1, 2019.3.6f1, 2020.1.0b2, 2020.2.0a4
Could not test with: 2017.4.38f1(package unavailable)
Reproducible with package versions: preview.6 - 0.4.0, preview.1 - 0.6.0
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Colliders of GameObject with Rigidbody component fail to collide with another GameObject when Rigidbody becomes Kinematic
- Shader cache uploads occur when the "Upload" parameter is disabled in the Cache Server settings
- "ApplySingleProperty clear overrides error" error when applying SerializedReference override to Prefab's nested Prefab
- About Unity window shows extended version numbers including staging tag
- Mono release JIT incorrectly replaces long multiplication with a left-shift operation
Resolution Note (fix version 0.8.0-preview.1):
Large microsecond time listings no longer drawn under the 'Jump to frame'