Search Issue Tracker
Fixed
Fixed in 6000.1.0a1
Votes
0
Found in
6000.0.18f1
Issue ID
UUM-79366
Regression
Yes
NullReferenceException Error is logged in Console when Converting Inspectors Preview to Floating Window
*Steps to reproduce:*
# Open any Project
# Create a Material in the Project Browser
# Select it and in the Inspector, in the Preview section click the Kebab menu and select "Convert to floating Window"
# Observe the Console
*Actual results:* Error "NullReferenceException: Object reference not set to an instance of an object" is printed in Console
*Expected results:* No Errors are logged
*Reproducible with versions:* 6000.0.7f1, 6000.0.18f1
*Not reproducible with versions:* 2021.3.43f1, 2022.3.45f1, 6000.0.6f1
*Tested on (OS):* macOS Sonoma