Search Issue Tracker
Fixed
Fixed in 1.11.2
Votes
0
Found in [Package]
1.11.1
Issue ID
ISXB-708
Regression
No
”NavigationSubmitEvent” and “NavigationCancelEvent” events are called multiple times in the Editor when the Input System’s Update Mode is set to “Process Events In Fixed Update”
How to reproduce:
1. Open the user’s attached “uitest1.zip” project
2. Enter Play Mode
3. Press the ESC or enter button
4. Observe the Console window
Expected result: a total of 4 logs are logged
Actual result: a total of 12 logs are logged
Reproducible with: 1.7.0, 1.8.0-pre.2 (2021.3.33f1, 2022.3.16f1, 2023.2.4f1, 2023.3.0a19)
Reproduced on: macOS 13.6.1 (Intel)
Not reproducible on: No other environment tested
Notes:
- not reproducible with “Process Events In Dynamic Update” Update Mode
- not reproducible in Standalone Player (macOS)
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- “FMOD failed to set the software format to the custom sample rate…” warnings are thrown as System Sample Rate value is being changed in Audio section of Project Settings window
- VFX Marquee selection does match the visual indicator
- “Invalid AABB aabb” errors are spammed when “Infinity” value is entered in Collider Component fields
- Editor Role does not sync with the MPPM Play Mode Scenario Role when entering Play mode
- Long asset names cause overlap with the “Find” function in search result tabs
Resolution Note (fix version 1.11.2):
A fix for this issue will be available in the next 1.11.x release of the Input System.
Resolution Note:
Fixed event handling when using Fixed Update processing where WasPressedThisFrame could appear to true for consecutive frames [ISXB-1006](https://issuetracker.unity3d.com/product/unity/issues/guid/ISXB-1006)