Search Issue Tracker
Fixed in 14.0.1
Votes
1
Found in [Package]
12.1.0
Issue ID
1415960
Regression
Yes
[HDRP] Switching to Default Layout, then switching to any other Layout with multiple Scene views makes lighting darker in HMD
Reproduction steps:
1. Open the attached "1415960.zip" project
2. Switch to Default Layout (Window > Layouts > Default)
3. Switch to 4 Split Layout (Window > Layouts > 4 Split)
4. Enter the Play mode and observe the Scene in the HMD
Expected result: The lighting in HMD is the same as in Unity
Actual result: The lighting in HMD is darker than in Unity
Reproducible with: 12.1.0 (2021.2.0b16), 12.1.6 (2021.2.19f1, 2021.3.0f1), 13.1.7 (2022.1.0b16), 14.0.0 (2022.2.0a7)
Not reproducible with: 7.7.1 (2019.4.38f1), 10.8.1 (2020.3.33f1), 12.0.0 (2021.2.0b15), 14.0.1 (2022.2.0a8), 14.0.2 (2022.2.0a10)
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- ScrollView speed is slower when entering Play mode
- UI Builder elements disappear and "Semantic - Unknown template name" error appears when changes to "Template" parameter are saved
- Renderers outside Light Probe hull use incorrect Ambient Probe values when "Renderer Light Probe Selection" is set to "Use Ambient Probe" and "Light Probes" on Mesh is set to "Blend Probes"
- ArgumentNullException error occurs when selecting a Camera in the Hierarchy with the Scene view open
- Clicking 'Open Editor Log' through the Console fails to open redirected Logs when relative Log files exist outside of the Project root
Resolution Note (fix version 14.0.1):
Fixed in: 14.0.1