[XR][Oculus] triggerPressed action is registered when index finger trigger has been lightly touched
Reproduction steps:
1. Open the attached project ("Input System.zip")
2. Open "Input System" scene
3. Enter Play mode
4. Make sure HMD is active
5. Lightly touch Index trigger
6. Open Console window
Expected result: triggerPressed action is registered when index finger trigger has been pressed more than halfway
Actual result: triggerPressed action is registered
Reproducible with: 2018.4.26f1, 2019.4.9f1
Not reproducible with: XR SDK 3.2.13 (2020.1.3f1, 2020.2.0a21)
Tested:
- Oculus Rift
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Console Warning -- KeyboardIconAtlas sprite Input Outline goes beyond the boundary of the Sprite rect.
- Reflection Probe “Probe Scene Editing Mode:” text is barely visible
- [HDRP] Game view doesn’t refresh after changing Camera Background Type until mouse moves over it
- Some Shaders appear twice in Material Shader selection menu
- Editor freezes with a StackOverflowException when certain asset types are assigned to a managed component in a SubScene via AddComponentObject
Resolution Note (2020.2.X):
The legacy implementation is hardcoded to use > 0.25f as its deadzone. This is now 0.5f in the XRSDK packages. To customize the deadzone, the best thing to do is use the analogue trigger value and use the new input system to define the deadzone, or calculate this yourself.