How to reproduce:
1. Open user-submitted project (ducktest2019)
2. Select the 'NewAudioMixer' in the Project window
3. Open the Audio Mixer window
4. Select the rightmost group
5. Attempt to adjust the New Group\Duck Volume value in the Audio Mixer window or the Send level value in the Inspector window
Expected result: the value of the slider in the group matches the value of the slider in the Inspector
Actual result: the value of the slider in the group does not match the value of the slider in the Inspector
Reproducible with: 2019.1.0a13, 2019.1.0b9, 2019.2.0a10
Not reproducible with: 2017.4.24f1, 2018.3.11f1, 2019.1.0a12
Comments (2)
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Required SpriteMask class (ID 331) is stripped when "Strip Engine Code" is enabled
- “Maximized serialized file backup not found” error is thrown when minimizing a window in a newly opened project
- Build stack trace contains invalid lines when building with IL2CPP using scripts with delegates containing generic types in the signature
- Entities Systems window has a “Show Full Player Loop” dropdown which does nothing when clicked after enabling “Show Full Player Loop”
- Entities Hierarchy Search “Show/Hide” button’s Lens Icon is blurry when the Editor is on an external monitor
michaelhighlandbuck
Mar 18, 2020 02:54
Still happening in 2019.3.2f1
TakaakiIchijo
Apr 13, 2019 15:56
It still occurs in 2019.1.0f1.