Search Issue Tracker
Fixed in 2022.2.X
Votes
0
Found in
2018.4
2019.4
2020.2.3f1
2020.3
2021.1
2021.2
Issue ID
1312900
Regression
No
SceneManager.sceneCount includes the unloaded Scene when it is called in SceneManager.sceneUnloaded event
Reproduction steps:
1. Open the attached "case_1312900.zip" project and Scenes/SampleScene scene
2. Add Scenes/Scene2 scene to the Hierarchy window
3. Enter the Play mode and observe the Console window
Expected result: "OnSceneUnloaded, scene count: 1" is logged
Actual result: "OnSceneUnloaded, scene count: 2" is logged
Reproducible with: 2018.4.32f1, 2019.4.20f1, 2020.3.0f1, 2021.1.0b9, 2021.2.0a7
Note: The issue is not reproducible when using EditorSceneManager.loadedSceneCount
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- VFX Graph Documentation dropdown button does nothing when clicked on the right side
- Required SpriteMask class (ID 331) is stripped when "Strip Engine Code" is enabled
- “Maximized serialized file backup not found” error is thrown when minimizing a window in a newly opened project
- Build stack trace contains invalid lines when building with IL2CPP using scripts with delegates containing generic types in the signature
- Entities Systems window has a “Show Full Player Loop” dropdown which does nothing when clicked after enabling “Show Full Player Loop”
Resolution Note (fix version 2022.2):
Fixed in: 2022.2.0a3