Search Issue Tracker
Fixed in 2020.2.X
Votes
0
Found in
2020.2.0a20
2020.2.0b2
Issue ID
1276959
Regression
Yes
SceneManager.GetActiveScene().name always returns level0 in Build
How to reproduce:
1. Open the user's attached "SceneManagerTest - Unity 2020.2.0b2.zip" project
2. Open the "SampleScene" Scene
3. Go to File -> Build And Run
4. Observe the text in the application
Expected result: The text in the application is "SampleScene" (SceneManager.GetActiveScene().name)
Actual result: The text in the application is "level0" (SceneManager.GetActiveScene().name)
Reproducible with: 2020.2.0a20, 2020.2.0b2
Not reproducible with: 2018.4.27f1, 2019.4.10f1, 2020.1.6f1, 2020.2.0a19, 2020.2.0b3
Note:
- The issue is not reproducible in the Editor
- The issue is reproducible with Windows and Mac Build
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Fixing Message Loss in UMPE During Domain Reload
- The Editor freezes when ScheduleReadOnly of IJobParallelForTransform with dependency is used
- Text is truncated in the Inspector when the display scale is set to 150%
- CancellationTokenSource(<timeout>) has incorrect cancellation status when used in WebGL Player
- VFX property value names are cut off when properties with 'Arc' are viewed in the VFX Blackboard
Resolution Note (fix version 2020.2):
Fixed in: 2020.2.0b3