Search Issue Tracker
Fixed in 2022.1.X
Fixed in 2020.3.X, 2021.2.X
Votes
0
Found in
2019.4
2020.3
2021.1
2021.1.22f1
2021.2
2022.1
Issue ID
1375960
Regression
No
Particle System uses incorrect Transform Matrices for Motion Vectors when Shadow casting is enabled
How to reproduce:
1. Open the user's attached project
2. Open scene Scenes/SampleScene
3. Press the Play button and observe the Game view
4. In the Hierarchy window, select the GameObject "TestPS"
5. In the Inspector view, under the Particle System component, select the Renderer module
6. Set the Cast Shadows setting to "On"
7. Observe the Game view
Expected result: the test texture (Particle) remains fully blurred
Actual result: the test texture (Particle) is only partially blurred
Reproducible with: 2019.4.32f1, 2020.3.21f1, 2021.1.27f1, 2021.2.1f1, 2022.1.0a13
Notes: the Particle flickers when Shadow casting is enabled from 2021.2.0a21 onwards
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Editor crashes and a window with "GetManagerFromContext: pointer to object of manager 'MonoManager' is NULL (table index 5)" error is shown when launching a freshly created project
- Editor Windows dragging behavior is erratic/glitchy when a specific multi-display setup is used and the Editor window is not on the main display
- Meta Quest missing an icon in Build Profiles window in U6.0
- Foldout arrow indent is misaligned in the Inspector when used for Arrays or Lists
- Material import pipeline strips properties when it is added with a script
Resolution Note (fix version 2022.1):
Fixed in 2022.2.0a4
Resolution Note (fix version 2022.1):
Fixed in 2022.1.0b7
Resolution Note (fix version 2021.2):
Fixed in 2021.2.11f1
Resolution Note (fix version 2020.3):
Fixed in 2020.3.28f1