Search Issue Tracker

Won't Fix

Votes

0

Found in [Package]

3.0.1

Issue ID

1228299

Regression

No

Importing the 2D Pixel Perfect package may result in exceeded path symbol count

Package: 2D Pixel Perfect

-

How to reproduce:
1. Create a new project. Make sure that the project path is at least 89 symbols long
2. Open the Package Manager window.
3. Import the 2D Pixel Perfect package
4. Observe the Console and Package Manager windows

Expected result: Package imports without any issues
Actual result: "Package Manager Window had an error while completing an operation: Could not find file" error is thrown and the Package Manager window breaks

Reproducible with: 2018.4.191f1, 2019.3.6f1, 2020.1.0b2, 2020.2.0a3
Could not test with: 2017.4.38f1(No package manager)

Workarounds:
- Shortening the path to the project
- Using symbolic links

Notes:
- The issue is not limited to the Pixel Perfect package, however, Pixel Perfect has a deep folder depth which results in a long path that showcases the underlying path length problem

  1. Resolution Note:

    The 2D Pixel Perfect Package will be fixed, we will try to shorten the paths to some of our sample assets.

    Currently, the issue will remain on the Package Manager side, so similar problems caused by exceeded path length can be encountered in certain situations. It was decided not to address this issue for the moment as it would require a major refactoring to be done. However, this may get addressed in the future once certain improvements will reach the Package Manager.

    Trying to reduce an overall project path is advised to work around this issue.