[HDRP] refraction proxy volumes projection breaks depending on camera orientation and position
* Create a scene with a transparent object inside a small room, make a reflection probe using proxy volume at the correct dimension
* Move the camera around, orientation and position, and notice how the projection isn't stable
You can grab this project : https://github.cds.internal.unity3d.com/alix-michel/TransparencyTestsHDRP