Search Issue Tracker
Fixed in 2021.2.X
Votes
0
Found in
2019.4
2020.3
2020.3.31f1
2021.2
Issue ID
1413189
Regression
No
Editor Window starts to glitch when resized between two monitors
How to reproduce:
1. Go into Mission Control settings on your macOS (System Preferences -> Mission Control)
2. Turn off "Displays have separate spaces"
3. Log off and login back into your macOS
4. Create a new empty project
5. Drag the Unity Editor window in between the two monitor screens
6. Expand the Unity Editor window to the side on the second monitor
Expected result: Nothing of note happens
Actual result: The widgets start to disappear after expanding the window
Reproducible with: 2019.4.38f1, 2020.3.34f1, 2021.2.0a2
Not reproducible with: 2021.2.0a3, 2021.3.1f1, 2022.1.0f1, 2022.2.0a11
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- “FMOD failed to set the software format to the custom sample rate…” warnings are thrown as System Sample Rate value is being changed in Audio section of Project Settings window
- VFX Marquee selection does match the visual indicator
- “Invalid AABB aabb” errors are spammed when “Infinity” value is entered in Collider Component fields
- Editor Role does not sync with the MPPM Play Mode Scenario Role when entering Play mode
- Long asset names cause overlap with the “Find” function in search result tabs
Resolution Note (fix version 2021.2):
Fixed in: 2021.2.0a3