Changing quality settings in runtime works incorrectly
Changing quality settings in runtime results in material brightness change. Materials can become brighter or darker.
Tested device:
Samsung Galaxy S2 (GT-I9100) with Android 4.0.3
Unity Versions:
4.1.5f1 (ed5ea3281df6)
4.2.0f4 (38efbd14869d)
4.3.0a5 (796335dfc9e5)
Add comment
All about bugs
View bugs we have successfully reproduced, and vote for the bugs you want to see fixed most urgently.
Latest issues
- Animation Clip with Legacy enabled does not play when Time.timeScale is set to 0 despite Update mode set to "Unscaled time"
- Rename is enabled on subfolder empty space - "Can't rename to empty name" warning
- SamplerState Property Missing Anisotropic Filtering
- Visual glitches when using Handles API
- The RGBA color values are inconsistent when comparing two identical colors set in the Inspector
3d_Game_Ready
Sep 26, 2014 06:43
Not sure if it's related but users report a black screen (as good as a crash) when the anti-aliasing is changed at runtime. Devices affected: Galaxy Note 3, Galaxy S5, Motorolla Droid Maxx and the HTC One. I didn't pick it up on my personal test devices and luckily launched a beta version otherwise there'd be red faces in the office.