Search Issue Tracker

Active

Under Consideration for 6000.0.X

Votes

0

Found in

6000.0.23f1

6000.1.0a7

Issue ID

UUM-84906

Regression

No

Adaptive Probe Volumes system places some Light Probes in incorrect positions when Generating Lighting

--

-

How to reproduce:
1. Open the attached “IN-85846“ project
2. Open the “DevScene“
3. Open the Lighting window (Window > Rendering > Lighting)
4. Press the “Generate Lighting“ button in the “Adaptive Probe Volumes” tab
5. Wait until the Baking process is finished
6. Open the Rendering Debugger window (Window > Analysis > Rendering Debugger) and check the “Display Probes” option
7. In the Scene window, fly around the scene and observe the placement of Light Probes

Expected result: Light Probes appear near light sources, accurately supporting their light emissions
Actual result: Some Probes appear in incorrect locations where no light source is present, resulting in the appearance of unintended illuminated areas

Reproducible in: 6000.0.23f1
Could not test with: 2021.3.45f1, 2022.3.50f1 (No APV package)

Reproducible on: Windows 11
Not reproducible on: No other environments tested